Chapter 6 Settings Menu
> 6.1 Setting Configuration
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
450
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
• Configuration data
Select from the following.
- Configuration information file
Transfers and applies any configuration data file selected by ETERNUSmgr.
- The last applied configuration information file
Applies the configuration information recorded in the device.
- The last applied configuration information file but one
Applies the configuration information recorded in the device.
- Current configuration
Applies the configuration information recorded in the device.
→ The [Set Configuration (Check)] screen appears.
• When downloading the configuration information file, clic k "The
last applied configuration information file", "The last applied
configuration information file but one", or "Current configuration"
link.
To save a configuration information file, save the file within one
minute after clicking each link. If the download dialog box is left
open for over a minute, the file saving operation may be
terminated and the file may not be downloaded successfully.
If the downloaded file cannot be opened, the download has failed,
try the download again.
• If the [Initialize] is selected in Mode, all of the volumes must be
formatted after rebooting the device.
• If there are no previous configurations, such as "The last applied
configuration information file" or "The last applied configuration
information file but one", they are not displayed for selection.
• To save a configuration information file, change the extension of
the file to ".cfg".
• In the following conditions, an error screen appears.
- When no configuration information file is selected
- When no data exists in the configuration information file
- When the configuration information file is in File Size Error
status
- When the configuration information file is abnormal