Appendix C Syslog Message List
> C.2 Syslog Message List
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
832
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
J 7A00LL0$ CE OUT TEMP
CE exhaust temperature error (WARNING) is detected.
J 7B000000 CE IN TEMP
CE intake temperature error (WARNING) is detected.
J 80SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss SMART
SMART is reported from the HDD.
J 80SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss Warning
HDD error is detected.
J 80SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss WarnSlow
SMART occurs because of Disk performance error in the HDD.
J 80SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss Slowdown
Disk performance error in the HDD is detected.
J 82SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss SMART
SMART is reported from the HDD (SATA).
J 82SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss Warning
HDD (SATA) error is detected.
J 84SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss SMART
SMART is reported from the SSD (Solid State Drive).
J 84SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss Warning
SSD (Solid State Drive) error is detected.
J 90xxGG0# PBC
PBC error is detected.
J C1NN0000 CM#NN Check-1
CM is rebooted.
J C1CC0000 CA#CC Check-1
CA is rebooted.
J C3cxNNss CM#NN MEMORY(zzzzMB) Correctable Error
Many correctable errors occurred in the CM memory.
J DA00GG0& DE OUT TEMP
DE exhaust temperature error (WARNING) is detected.
J DB00GG00 DE IN TEMP
DE intake temperature error (WARNING) is detected.
M 0732uuyy Remote Copy Path (MID#uu PORT#yy) Not Available
Disconnection of a REC path between cabinets is detected.
M 13CF11ee REC Automatic HALT or ERROR occured. (ee)
Occurrence of automatic HALT in the REC is detected.
M 21810xxx RAID Group#0xxx REBUILD to HS (Recovered end)
Rebuilding to HS is complete, but Bad Data (data lost identifier) exists.
M 21810xxx RAID Group#0xxx REBUILD to DV (Recovered end)
Rebuilding to DV (replaced disk) is complete, but Bad Data (data lost
identifier) exists.
Event type code Upper: Message