Chapter 5 Configuration Menu
> 5.4 Host Interface Management
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
313
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
[iSCSI Settings]
- iSCSI Name (required)
Specify the iSCSI Name of the iSCSI-CA Port.
When setting the default iSCSI Name, click the [Default] button.
- Alias Name
Specify the Alias Name of the iSCSI-CA Port.
[Transfer Rate]
Set the transfer rate of the iSCSI-CA Port.
- 1Gbit/s
The transfer rate is 1Gbit/s (full-duplex).
[CHAP]
Select ON (Enabled) or OFF (Disabled) for the CHAP of the iSCSI-CA Port.
- ON
Enables the CHAP
Enter the user name for the CHAP and the current password.
To change the password, enter a new password.
- OFF
Disables the CHAP
[Affinity Mode]
Select ON (Enabled) or OFF (Disabled) for the Host-Affinity function of the iSCSI-CA
Port.
- ON
Enables the Host-Affinity function of the iSCSI-CA Port.
In this case, [Set LUN Mapping] is disabled and the Host-Affinity function is enabled
for the iSCSI-CA Port.
- OFF
Disables the Host-Affinity function of the iSCSI-CA Port.
In this ca se, [Set LUN M apping] is enable d and the Host-Affinity fu nction is disabled
for the iSCSI-CA Port.
• When the Execution Result screen appears, check the results
([Set CA Parameters (Ping Execution Result)] screen).
When setting the user name and/or the password, check the
"Change" checkbox.