- When the port of the local device is [Initiator (*1)]
Normal
All the paths between the relevant port and the remote devices are normal.
Error
All the paths between the relevant port and the remote devices are in error status.
The suspected error location cannot be specified. Refer to "Path status codes and
troubleshooting".
Error (Partial)
The path status between the relevant port and some remote device(s) is/are in error
status.
When checking the path status between the initiator and target devices, and there is a
path between the local and remote devices, check the loopback. If there is more than
one path between the local device and remote device, it will indicate that some of the
loopback results cannot be received.
Unknown
Unknown path configuration details are found in the device.
When deleting a path configuration, delete the relevant information in the [Create
Advanced Copy Information] menu. And then set the updated path configuration file to
the device in the [Set Advanced Copy Path] menu.
*1: Only when the connected destination is ETERNUS6000.
When there is more than one path from the port of the local device, and that port status is
"Error" or "Error (Partial)", the path statuses are displayed together in the same cell.
Path status codes and troubleshooting
Displayed contents
Auto, Target (*1)
- Error (M)
Contact your maintenance engineer.
- Error (D)
Check if the path setting is correct.
- Error (I)
The suspected error location is a local device FCRA or iSCSI-RA. Check the FCRA or
iSCSI-RA status for the local device.
- Error (T)
The suspected error location is a remote device FCRA or iSCSI-RA. Check the FCRA or
iSCSI-RA status for the remote device.
- Error (N)
The suspected error location is a remote device. Check the status of the remote device.
- Error (C)
The suspected error location is the cable. Check the cable status.
- Error (S)
The suspected error location is the switch or switch setting. Check the switch status or the
switch setting.