3Com MSR 50 Network Router User Manual


  Open as PDF
of 2742
 
1751
display ipv6 interface tunnel
Syntax display ipv6 interface tunnel number
View Any view
Parameter number: Tunnel interface number.
Description Use the
display ipv6 interface tunnel command to display IPv6 information
about a tunnel interface.
Example # Display IPv6 information about interface Tunnel0.
<Sysname> display ipv6 interface tunnel 0
Tunnel0 current state :UP
Line protocol current state :UP
IPv6 is enabled, link-local address is FE80::101:101
Global unicast address(es):
2002:101:101::1, subnet is 2002::/16
Joined group address(es):
FF02::1:FF01:101
FF02::1:FF00:1
FF02::2
FF02::1
MTU is 1500 bytes
ND reachable time is 30000 milliseconds
ND retransmit interval is 1000 milliseconds
Hosts use stateless autoconfig for addresses
Tunnel source Source address of the tunnel interface
destination Destination address of the tunnel interface
Tunnel keepalive Whether the GRE keepalive function is enabled
Tunnel protocol/transport Tunnel protocol/transport protocol
GRE key Secret key for tunnel interfaces use
Checksumming of GRE packets Whether GRE packet checksum is enabled
Last 300 seconds input Amount of inbound traffic per second in the last five
minutes, in bytes and in packets respectively
Last 300 seconds output Amount of outbound traffic per second in the last five
minutes, in bytes and in packets respectively
xxx packets input, xxx bytes Cumulative amount of inbound traffic, in packets and in
bytes respectively
input error Number of wrong packets in all inbound packets
xxx packets output, xxx bytes Cumulative amount of outbound traffic, in packets and in
bytes respectively
output error Number of wrong packets in all outbound packets
Table 468 Description on the fields of the display interface tunnel command
Field Description