3Com MSR 50 Network Router User Manual


  Open as PDF
of 2742
 
674 CHAPTER 45: CPOS INTERFACE CONFIGURATION COMMANDS
Cpos4/0 CT1 3 is up
Frame-format ESF, clock master, loopback not set
(Some information about T1 channels is omitted.)
Cpos4/0 CT1 83 is up
Frame-format ESF, clock master, loopback not set
Cpos4/0 CT1 84 is up
Frame-format ESF, clock master, loopback not set
display controller cpos e1
Syntax display controller cpos cpos-number e1 e1-number
View Any view
Parameter cpos-number: CPOS interface number.
e1-number: Number of an E1 channel on a CPOS interface, in the range 1 to 63.
Description Use the
display controller cpos e1 command to display the physical layer
configuration information of the specified E1 channel on the specified CPOS
interface.
Table 122 Description on the fields of the display controller cpos command
Field Description
Cpos4/0 current state Current physical state of the CPOS interface.
Description Interface description.
Frame-format SDH, multiplex
AU-3, clock master, loopback
not set
Physical layer information of the CPOS interface: the
framing format is set to SDH, AU-3 path is adopted, master
clock (internal clock signal) is used, and loopback is
disabled.
Tx: J0: 0x01, J1: “NetEngine”,
C2: 0x02
The sent overhead bytes.
Rx: J0: 0x01, J1: “NetEngine”,
C2: 0x02
The received overhead bytes.
Regenerator section: Alarm and error statistics about the regeneration section.
Multiplex section: Alarm and error statistics about the multiplex section.
Higher order path(VC-3-x): Alarm and error statistics about the higher-order path. The
x in “VC-3-x” indicates the path number. When adopting
AU-3 path, one STM-1 has three higher-order paths
because it is multiplexed by three VC-3s. In the AU-4 path,
there is one higher-order path VC-4.
Alarm: Alarm statistics.
Error: Error statistics.
Cpos4/0 CT1 1 is up The current physical state of T1 channel 1 of the CPOS
interface 4/0.
Frame-format ESF, clock master,
loopback not set
Physical layer information of T1 channels: the framing
format is set to ESF, master clock (internal clock signal) is
used, and loopback is disabled.