Use the undo data-coding command to restore the default.
By default, data inversion is disabled.
To prevent 7e in valid data from being taken for stuffing characters, HDLC inserts a
zero after every five ones in the data stream. Then, HDLC inverts every one bit into
a zero and every zero bit into a one. This ensures at least one out of every eight
bits is a one. When AMI encoding is adopted on a T1 interface, the use of data
inversion can eliminate the presence of multiple consecutive zeros.
At the two ends of the line, the same data inversion setting must be adopted.
Example # Enable user data inversion on CT1/PRI interface T1 2/0.
<Sysname> system-view
[Sysname] controller t1 2/0
[Sysname-T1 2/0] data-coding inverted
display controller t1
Syntax display controller t1 [ interface-number ]
View Any view
Parameter interface-number: Interface number. In conjunction with the t1 keyword, it
specifies a CT1/PRI interface.
Description Use the
display controller t1 command to display information about one
specified or all CT1/PRI interfaces.
This command displays the following information about the specified interface:
Physical state
Cable type
Framing
Clock source (mode)
Line code format
Loopback mode
Line idle code type
Interframe filling tag type
Alarm states
Error statistics gathered at 15-minute intervals during the last 24 hours
Example # Display information about interface T1 2/0.
<Sysname> display controller t1 2/0
T1 2/0 current state :DOWN
Description : T1 2/0 Interface
Basic Configuration: