Parameter length: The maximum number of consecutive information frames the router can
send before receiving an acknowledgment from the peer, in the range of 1 to 127.
Description Use the llc2 receive-window command to configure the maximum number of
consecutive information frames the router can send before receiving an
acknowledgment from the peer.
Use the
undo llc2 receive-window command to restore the default setting.
By default, the maximum number of consecutive information frames the router
can send before receiving an acknowledgment from the peer is 7.
Example # Set the maximum number of consecutive information frames the router can
send before receiving an acknowledgment from the peer to 10 on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 receive-window 10
llc2 timer ack
Syntax llc2 timer ack mseconds
undo llc2 timer ack
View Ethernet interface view
Parameter mseconds: LLC2 acknowledgment waiting time in milliseconds. The effective
range is 1 to 60,000.
Description Use the
llc2 timer ack command to configure the LLC2 acknowledgment
waiting time, namely the maximum length of time the router waits for an
acknowledgment from the peer after sending an LLC2 frame.
Use the
undo llc2 timer ack command to restore the default setting.
By default, the LLC2 acknowledgment waiting time is 200 milliseconds.
Example # Set the LLC2 acknowledgment waiting time to 10 milliseconds on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer ack 10
llc2 timer ack-delay
Syntax llc2 timer ack-delay mseconds
undo llc2 timer ack-delay