3Com MSR 50 Network Router User Manual


  Open as PDF
of 2742
 
2441
Use the undo info-center source command to remove the specified output
rules.
By default, the output rules for the system information are listed in Table 633.
This command can be used to filter and redirect system information.
For example, the user can set to output log information with severity higher than
warnings to the log host, and information with severity higher than informational
to the log buffer. The user can also set to output trap information of the IP module
to a specified output direction.
Note that:
If you do not use the module-name argument to set output rules for a module,
the module uses the default output rules or the output rules set by the default
keyword; otherwise the module uses the output rules separately set for it.
When you use the module-name argument to separately set the output rules
for a module, the default output rules for the module become: Log and trap
information is enabled, with severity being informational; debug information is
disabled, with severity being debugging.
After you separately set the output rules for a module, you must use the
module-name argument to modify or remove the rules. The new configuration
by using the default keyword is invalid on the module.
Example # Set the output channel for the log information of VLAN module to snmpagent
and to output information with severity being emergencies.
<Sysname> system-view
[Sysname] info-center source vlan channel snmpagent log level emergencies
Table 633 Default output rules for different output directions
Output
direction
Modules
allowed
LOG TRAP DEBUG
Enabled/
disabled Severity
Enabled/
disabled Severity
Enabled/
disabled Severity
Console default (all
modules)
Enabled warnings Enabled debuggin
g
Enabled debuggin
g
Monitorin
g terminal
default (all
modules)
Enabled warnings Enabled debuggin
g
Enabled debuggin
g
Log host default (all
modules)
Enabled informatio
nal
Enabled debuggin
g
Disabled debuggin
g
Trap
buffer
default (all
modules)
Disabled informatio
nal
Enabled warnings Disabled debuggin
g
Log buffer default (all
modules)
Enabled warnings Disabled debuggin
g
Disabled debuggin
g
SNMP
NMS
default (all
modules)
Disabled debuggin
g
Enabled warnings Disabled debuggin
g
Log file default (all
modules)
Enabled debuggin
g
Enabled debuggin
g
Disabled debuggin
g