RMON CONFIGURATION COMMANDS
display rmon alarm
Syntax display rmon alarm [ entry-number ]
View Any view
Parameter entry-number: Index of an RMON alarm entry, in the range 1 to 65535. If no entry
is specified, the configuration of all alarm entries is displayed.
Description Use the
display rmon alarm command to display the configuration of the
specified or all RMON alarm entries.
Related command: rmon alarm.
Example # Display the configuration of all RMON alarm table entries.
<Sysname> display rmon alarm
Alarm table 1 owned by user1 is VALID.
Samples type : absolute
Variable formula : 1.3.6.1.2.1.16.1.1.1.4.1<etherStatsOctets.1>
Sampling interval : 10(sec)
Rising threshold : 50(linked with event 1)
Falling threshold : 5(linked with event 2)
When startup enables : risingOrFallingAlarm
Latest value : 0
Table 608 Description on the fields of the display rmon alarm command
Field Description
Alarm table Alarm entry index, 1 in this example
owned by Owner of the entry, user1 in this example
VALID Status of the entry identified by the index (VALID means the entry is
valid, and UNDERCREATION means invalid. You can use the display
rmon command to view the invalid entry and with the display
current-configuration and display this commands you cannot view
the corresponding rmon commands.)
Samples type The sampling type (absolute in this example)
Variable formula Formula for the sampling value
Sampling interval Sampling interval
Rising threshold Alarm rising threshold (When the sampling value is bigger than or
equal to this threshold, a rising alarm is triggered.)
Falling threshold Alarm falling threshold (When the sampling value is smaller than or
equal to this threshold, a falling alarm is triggered.)