3Com MSR 50 Network Router User Manual


  Open as PDF
of 2742
 
2233
vrrp vrid timer advertise
Syntax vrrp vrid virtual-router-id timer advertise adver-interval
undo vrrp vrid virtual-router-id timer advertise
View Interface view
Parameter virtual-router-id: VRRP standby group number, in the range 1 to 255.
adver-interval: Interval at which the master in the specified standby group sends
VRRP advertisements. It ranges from 1 to 255 seconds.
Description Use the
vrrp vrid timer advertise command to configure the interval for
Master in the specified standby group to send VRRP advertisements.
Use the
undo vrrp vrid timer advertise command to restore the default.
By default the interval for Master in the specified standby group to send VRRP
advertisements is 1 second.
Note that:
Before executing the command, create a standby group on an interface and
configure the virtual IP address of the standby group.
Routers in the same VRRP standby group must use the same Adver_Timer
setting.
Example # Set the master in standby group 1 to send VRRP advertisements at intervals of
five seconds.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] vrrp vrid 1 virtual-ip 10.1.1.1
[Sysname-Ethernet1/0] vrrp vrid 1 timer advertise 5
vrrp vrid track
Syntax vrrp vrid virtual-router-id track track-entry-number [ reduced priority-reduced ]
undo vrrp vrid virtual-router-id track [ object-number ]
View Interface view
Parameters virtual-router-id: VRRP standby group number, in the range 1 to 255.
track track-entry-number: Specifies a Track object to be monitored by its number.
track-entry-number ranges from 1 to 1024.