13
FUNDAMENTAL CT1/PRI INTERFACE
CONFIGURATION COMMANDS
alarm-threshold
Syntax alarm-threshold { ais { level-1 | level-2 } | lfa { level-1 | level-2 | level-3 | level-4 } |
los { pulse-detection | pulse-recovery } value }
undo alarm-threshold
View CT1/PRI interface view
Parameter ais: Sets the alarm threshold of alarm indication signal (AIS), which can be level-1
and level-2.
The level-1 keyword specifies to generate an AIS alarm when the number of 0s
in the bit stream of an SF or ESF frame is less than or equal to 2.
The level-2 keyword specifies to generate an AIS alarm when the number of 0s
is less than or equal to 3 in the bit stream of an SF frame or less than or equal
to 5 in the bit stream of an ESP frame.
By default, level-1 AIS alarm threshold applies.
lfa: Sets the loss of frame align (LFA) alarm threshold, which can be level-1,
level-2, level-3, and level-4.
The level-1 keyword specifies to generate an LFA alarm when two of four
frame alignment bits are lost.
The level-2 keyword specifies to generate an LFA alarm when two of five
frame alignment bits are lost.
The level-3 keyword specifies to generate an LFA alarm when two of six frame
alignment bits are lost.
The level-4 keyword applies only to ESF frames. It specifies to generate an LFA
alarm when errors are detected in four consecutive ESF frames.
By default, level-1 LFA alarm threshold applies.
los: Sets a loss of signal (LOS) alarm threshold, which can be pulse-detection (for
the pulse detection duration threshold with LOS) and pulse-recovery (for the
pulse threshold with LOS).
The threshold of pulse-detection, in units of pulse intervals, ranges from 16 to
4,096 and defaults to 176.
The threshold of pulse-recovery, ranges from 1 to 256 and defaults to 22.