3Com MSR 50 Network Router User Manual


  Open as PDF
of 2742
 
2663
req-callingcategory value: Specifies the send calling category signal value, in the
range 1 to 16.
req-currentcallednum-in-groupc value: Specifies the send current called
number signal in Group C state, in the range 1 to 16.
req-currentdigit value: Specifies the send current digit signal, in the range 1 to
16.
req-firstcallednum-in-groupc value: Specifies the send first digit signal value in
Group C state, in the range 1 to 16.
req-firstcallingnum value: Specifies the send calling number signal value, in the
range 1 to 16.
req-firstdigit value: Specifies the send first digit signal value, in the range 1 to 16.
req-lastfirstdigit value: Specifies the send last digit signal value, in the range 1 to
16.
req-lastseconddigit value: Specifies the send last second digits signal value, in
the range 1 to 16.
req-lastthirddigit value: Specifies the send last three digits signal value, in the
range 1 to 16.
req-nextcallednum value: Specifies the send next called number signal value, in
the range 1 to 16.
req-nextcallingnum value: Specifies the send next calling number signal value, in
the range 1 to 16.
req-switch-groupb value: Specifies the changeover to Group B signal value, in
the range 1 to 16.
subscriber-abnormal value: Specifies the subscriber’s line abnormal signal value,
in the range 1 to 16.
subscriber-busy value: Specifies the subscriber’s line busy signal value, in the
range 1 to 16.
subscriber-idle value: Specifies the subscriber’s line idle value, in the range 1 to
16. It configures the R2 KB signal used for describing the called subscriber’s line
status, for example, whether the line is idle. It acknowledges and controls call
connection. If your router is connected to a PBX, change the KB value on the
router to that used on the PBX, in case different KB values are used. If your router
is connected to another router, you only need to make sure that the same KB
signal value is used between them.
The defaults vary by national variant.
Description Use the
register-value command to configure R2 register signal values.
Use the
undo register-value command to restore the defaults.