578 CHAPTER 37: ISDN CONFIGURATION COMMANDS
Description Use the isdn L3-timer command to configure the duration of an ISDN protocol
L3 timer. Use the undo isdn L3-timer command to restore the default duration of
the ISDN L3 timer on the interface.
You can view the default durations of the L3 timers in the ISDN protocol by
executing the display isdn parameters command.
Example # Set the duration of the L3 timer T301 on the interface BRI 1/0 to 160 seconds.
<Sysname> system-view
[Sysname] interface bri 1/0
[Sysname-Bri1/0] isdn l3-timer t301 160
isdn link-mode
Syntax isdn link-mode p2p
undo isdn link-mode
View ISDN BRI interface
Parameter None
Description Use the
isdn link-mode p2p command to configure a BRI interface to operate in
the point-to-point mode.
Use the
undo isdn link-mode command to restore the default BRI interface
operating mode.
By default, a BRI interface operates in the point-to-multipoint mode, in which a
BRI interface operating on the network side can have multiple end devices
attached to it.
Example # Configure BRI1/0 interface to operate in the point-to-point mode.
<Sysname> system-view
[Sysname] interface bri 1/0
[Sysname-Bri1/0] isdn link-mode p2p
isdn number-property
Syntax isdn number-property number-property [ calling | called ] [ in | out ]
undo isdn number-property [ calling | called ] [ in | out ]
View ISDN interface view
Parameter number-property: Type and number scheme of ISDN numbers. The argument takes
on a hex value in the range of 0 to 7F. When it is expressed in 8 bits, bits 1 through
4 represent the code scheme, bits 5 through 7 represent the code type, and bit 8 is