3Com MSR 50 Network Router User Manual


  Open as PDF
of 2742
 
2616 CHAPTER 173: VOIP CONFIGURATION COMMANDS
undo type
View Analog E&M voice subscriber line view
Parameter 1, 2, 3 and 5: Correspond respectively to the four signal types of analog E&M
subscriber lines, i.e. type 1, 2, 3 and 5.
Description Use the
type command to configure the analog E&M subscriber line signal type.
Use the undo type command to cancel the existing settings.
By default, the analog E&M subscriber line signal type is type 5.
This command is only applicable to the analog E&M subscriber line.
Example # Configure subscriber line 1/0 analog E&M subscriber line type as type 3.
<Sysname> system-view
[Sysname] voice-setup
[Sysname-voice] subscriber-line 1/0
[Sysname-voice-line1/0] type 3
vad-on
Syntax vad-on
undo vad-on
View POTS/VoIP/VoFR entity view
Parameter None
Description Use the
vad-on command to enable voice activity detection (VAD) function.
Use the
undo vad-on command to disable silence detection function.
By default, the silence detection function is disabled.
Note that G.711 codec does not support VAD.
The voice activity detection (VAD) discriminates between silence and speech on a
voice connection according to their energies. VAD reduces the bandwidth
requirements of a voice connection by not generating traffic during periods of
silence in an active voice connection. Speech signals are generated and
transmitted only when an active voice segment is detected. Researches show that
VAD can save the transmission bandwidth by 50%.
Related command: cng-on.
Example # Enable VAD on POTS voice entity 10.