3Com MSR 50 Network Router User Manual


  Open as PDF
of 2742
 
2653
undo dl-bits { answer | blocking | clear-back | clear-forward | idle | seize |
seizure-ack | release-guard } { received | transmit }
View R2 CAS view
Parameter answer: Answer signal of R2 line signaling.
blocking: Blocking signal of R2 line signaling.
clear-back: Clear-back signal of R2 line signaling.
clear-forward: Clear-forward signal of R2 line signaling.
idle: Idle signal of R2 line signaling.
seize: Seizure signal of R2 line signaling.
seizure-ack: Seizure acknowledgement signal of R2 line signaling.
release-guard: Release guard signal of R2 line signaling.
received: Indicates that the signaling setting applies to received R2 line signals.
transmit: Indicates that the signaling setting applies to transmitted R2 line signals.
ABCD: ABCD bit pattern of R2 line signaling, in the range of 0000 to 1111.
Description Use the
dl-bits command to configure the ABCD bit pattern for R2 signals.
Use the
undo dl-bits command to restore the defaults.
This command applies to R2 signaling only.
You may need to use this command to accommodate to the ABCD bit pattern
schemes used in different countries.
When you modify the ABCD bit pattern of a signal, you need to modify the ABCD
bit pattern of other signals accordingly so that the whole signaling system can
work normally.
Table 695 Default values of signals in R2 digital line signaling
Signal Default rx-bits ABCD Default tx-bits ABCD
Answer 0101 0101
Blocking 1101 1101
Clear-back 1101 1101
Clear-forward 1001 1001
Idle 1001 1001
Seize 0001 0001
Seizure-ack 1101 1101
Release-guard 1001 1001