3Com MSR 50 Network Router User Manual


  Open as PDF
of 2742
 
223
Description Use the error-diffusion restraint config command to set the three parameters
in error packet diffusion restraint.
Use the
undo error-diffusion restraint enable command to restore the
default settings of the three parameters.
By default, the error packet detect timer is set to 30 seconds, the renew timer is
set to 600 seconds, and the error packet ratio threshold is 20.
The setting of renew timer must be at least four times that of the error packet
detect timer. If the total number of the packets received during detect-timer is less
than 100, error packets are not counted.
n
The support for these two commands varies with device models.
These two commands apply to CT1/PRI interfaces and CE1/PRI interfaces only.
Example # Set the error packet detect timer to 100 seconds, the renew timer to 2400
seconds, and the error packet ratio threshold to 15.
<Sysname> system-view
[Sysname] error-diffusion restraint config 100 2400 15
error-diffusion restraint enable
Syntax error-diffusion restraint enable
undo error-diffusion restraint enable
View System view
Parameter None
Description Use the
error-diffusion restraint enable command to enable error packet
diffusion restraint.
Use the
undo error-diffusion restraint enable command to disable error
packet diffusion restraint.
By default, the function is disabled.
n
The support of these two commands varies with device model.
These two commands apply to CT1/PRI interfaces and CE1/PRI interfaces only.
Example # Enable error packet diffusion restraint.
<Sysname> system-view
[Sysname] error-diffusion restraint enable