240 CHAPTER 15: T1-F INTERFACE CONFIGURATION COMMANDS
<Sysname> display ft1 serial 2/0
Serial2/0
Input: 0 packets, 0 bytes
0 broadcasts, 0 multicasts
0 errors, 0 runts, 0 giants
0 CRC, 0 align errors, 0 overruns
0 dribbles, 0 aborts, 0 no buffers
0 frame errors
Output:0 packets, 0 bytes
0 errors, 0 underruns, 0 collisions
0 deferred
Basic Configuration:
Work mode is T1 framed, Cable type is 100 Ohm balanced.
Frame-format is esf, fdl is none, Line code is b8zs.
Source clock is slave, Data-coding is normal.
Idle code is ff, Itf type is ff, Itf number is 2
Loop back is not set.
Alarm State:
Receiver alarm state is Loss-of-Signal.
Transmitter is sending remote alarm.
Pulse density violation detected.
SendLoopCode History:
inband-llb-up:0 times, inband-llb-down:0 times.
fdl-ansi-llb-up:0 times, fdl-ansi-llb-down:0 times.
fdl-ansi-plb-up:0 times, fdl-ansi-plb-down:0 times.
BERT state:(stopped, not completed)
Test pattern: 2^15, Status: Not Sync, Sync Detected: 0
Time: 0 minute(s), Time past: 0 minute(s)
Bit Errors (since test started): 0 bits
Bits Received (since test started): 0 Kbits
Bit Errors (since latest sync): 0 bits
Bits Received (since latest sync): 0 Kbits
Historical Statistics:
Last clearing of counters: Never
Data in current interval (285 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Ais Alarm Secs, 286 Los Alarm Secs
7 Slip Secs, 286 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 286 Unavail Secs
Data in Interval 1:
0 Line Code Violations, 0 Path Code Violations
0 Ais Alarm Secs, 901 Los Alarm Secs
22 Slip Secs, 901 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 901 Unavail Secs
Data in Interval 2:
0 Line Code Violations, 0 Path Code Violations
0 Ais Alarm Secs, 900 Los Alarm Secs
23 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
Total Data (last 2 15 minute intervals):
0 Line Code Violations, 0 Path Code Violations
0 Ais Alarm Secs, 2087 Los Alarm Secs
52 Slip Secs, 2087 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 2087 Unavail Secs
Table 20 Description on the fields of the display ft1 serial command
Field Description
Serial2/0 Interface type and number
Basic Configuration Basic configurations for the interface
Input
Output
Statistics about the input and output
Work mode T1 interface operating mode, T1 framed in this
sample output