Chapter 23 Sub Oscillation Stabilisation Timer
4.Register
4. Register
4.1 WPCRH: Sub oscillation stabilisation timer Control Register
This register is used to select interval time, clear the timer, control interrupt, control timer stop etc., and
confirm the states.
WPCRH: Address 04CAh (Access: Byte)
(For the attributes, refer to “Meaning of Bit Attribute Symbols (Page No.10)”.)
(Refer to “8. Caution (Page No.309)”.)
Bit7: Sub oscillation stabilisation timer interrupt request flag
The sub oscillation stabilisation timer interrupt request flag bit is set to “1” at the falling edge of the
selected interval period output.
Bit6: Interrupt request enable
If the interrupt request enable bit is set to “1” an interrupt request is enabled.
If the sub oscillation stabilisation timer interrupt request flag is (WIF=“1”), and if the interrupt request
enable bit (WIE) is set to “1”, an interrupt request is immediately generated.
Bit5: Timer operation enable
Bit4-3: Reserved bit Be sure to write “0”. The read value is “0”.
Bit2-1: Interval period selection
Bit0: Timer clear
The timer is also cleared by INITX terminal input and watchdog reset.
Notes 1: Initial value can be set using the setting initialization reset (INIT terminal input,
7 6 5 4 3 2 1 0 bit
WIF WIE WEN WS1 WS0 WCL
0 0 0 X X 0 0 1 Initial value (At INIT) *1
R(RM1),W R/W R/W RX/W0 RX/W0 R/W R/W R1,W Attribute
WIF Read Operation Write Operation
0 Without interrupt request Clears the interrupt request flag
1 With interrupt request Writing does not affect operation
WIE Operation
0 Interrupt request is prohibited
1 Interrupt request enable
WEN Operation
0 Stops timer operation
1 Enables timer operation
WS1 WS0
Interval period (F
CL-SUB
= 32.768kHz)
00
2
10
/F
CL-SUB
(31.25ms)
01
2
13
/F
CL-SUB
(0.25s)
10
2
14
/F
CL-SUB
(0.50s)
11
2
15
/F
CL-SUB
(1.00s)
WCL Operation
0 Clears the sub oscillation stabilisation timer.
1 Writing does not affect write operation.