Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-345DATA-BD (Network Control Circuit Pack)
10
3. From the form resulting from the list data command, choose a
Network Control Data Channel (DATA-CHL) whose port field value
indicates that it is on the same carrier (A or B) as the Network
Control circuit pack to be reset.
4. Issue the test data-module <ext> long command using the
extension for the DATA-CHL chosen in Step 3.
!
WARNING:
Issuing this command drops all data channel extensions. See
DATA-CHL (Network Control Data Channel) Maintenance
documentation first.
If the red LED stays on, then replace the circuit pack.
b. The circuit pack has been logically administered but not physically
installed. The alarm is cleared when the circuit pact is installed.
c. This error indicates transient communications problems with this circuit
pack. This error is not service-affecting and no action is required.
d. This error indicates the circuit pack has reported a hardware failure on the
circuit pack. The circuit pack should be replaced.
e. This error can be ignored, but look for other errors on this circuit pack.
f. This error is not service-affecting and no action is required.
g. This error indicates the DATA-BD portion of the Network Control circuit
pack is out-of-service. Since the Network Control circuit pack cannot be
reset via the reset board PCSS command, the Data Channel Reset Test
(#107) in the Long Test Sequence for the DATA-CHL and DATA-CON
must be used to reset it as follows:
1. Issue the list data command to determine if one or more Network
Control Data Channels (DATA-CHLs) are administered.
NOTE:
A Network Control Data Channel (DATA-CHL) is identified by
a "type" value of "netcon."
2. If a Network Control Data Channel (DATA-CHL) is not administered,
use the add data-module [<ext> | next] command to administer a
DATA-CHL.
3. From the form resulting from the list data command, choose a
Network Control Data Channel (DATA-CHL) whose port field value
indicates that it is on the same carrier (A or B) as the Network
Control circuit pack to be reset.