DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-21busyout tone-clock
8
busyout tone-clock
This command places the specified tone/clock in a maintenance busy state. No
periodic or scheduled tests are performed on the busied out object until it is
released. When the object is maintenance busy it is deactivated (no call
processing activity may include the busied object). Warning alarms (error type
18) are generated on each tone clock circuit pack busied out, so that INADS can
determine the state of the objects. The command, release tone-clock,
reactivates the specified tone/clock.
Output
The following example is a display of the busyout tone-clock command.
Field descriptions
Maintenance Name
Type of busied out maintenance object: TDM-BUS
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout
tone-clock
location
Physical location (PC)
Examples:
busyout tone-clock 01c
busyout tone-clock 03d
init
inads
craft
1 (one) none
Port
Tone/clock board address (cabinet-carrier)
Maintenance Name
Circuit pack name: TONE-PT, TDM-CLK, TONE-BD
busyout tone-clock 1a SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01A TONE-PT PASS
01A TDM-CLK PASS
01A TONE-BD PASS
Command successfully completed