DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-403DID-DS1 (DS1 DID Trunk)
10
1000 ABORT The port may be busy with a valid call. Issue the display port PCSSpp
command to determine the trunk group/member number of the port. Use
the status trunk command to determine the service state of the port. If the
service state indicates that the port is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the Error Log table for a description
of this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1 minute intervals for a
maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1006 ABORT The test was aborted because the trunk is out of service.
1. Use the status trunk command to verify that the trunk is out of
service.
2. If the trunk is out of service, determine why.
3. If it is OK to put the trunk back in service, issue the release trunk
command to put the trunk back in service, and then retry the test.
4. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT Could not allocate resources to run this test.
1. Retry the command at 1 minute intervals for a maximum of 5 times.
If the test continues to abort, escalate the problem
FAIL Test failed due to Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If test continues to fail, escalate the problem.
PASS Trunk translation has been updated successfully. The current trunk states
kept in the DS1 Interface circuit pack and switch software are consistent. If
the trunk is busied out, the test does not run, but returns PASS. To verify
that the trunk is in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release-trunk command to put trunk back into in-service.
3. Retry the test command.
Table 10-131. TEST #36 Port Audit and Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page