Page 10-625EXP-INTF (Expansion Interface Circuit Pack)
10
1033 ABORT The test cannot run because either one or both of the Expansion Interface
circuit packs on this link are busied out or an Expansion Interface circuit
pack is not present on the opposite end of the fiber.
1. If Expansion Interface is busied out, issue the release board PCSS
command.
2. Examine results of Tests #237 and #238.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 3 retries.
FAIL The test tone was not detected correctly in either direction.
1. Run the test for the Active Tone-Clocks on the Port Networks for which
the Expansion Interface circuit pack under test provides a link. This will
determine if the dial tone is being supplied.
2. Check for disconnected transmit or receive fiber on both ends of the
fiber. Make sure both endpoint circuit packs are inserted and have no
on-board alarms.
1 or 2 FAIL The test tone was detected correctly in only one direction.
1. Run the test for the Active Tone-Clocks on the Port Networks for which
the defective Expansion Interface circuit pack provides a link. This
determines if the dial tone is being supplied.
2. Check for disconnected transmit or receive fibers on both ends of the
fiber.
3. If Test #238 is failing, refer to procedures for Test #238.
4. If Error Type 2305 has been logged against this Expansion Interface
circuit pack, or the Expansion Interface circuit pack on the opposite end
of its fiber, in the last five minutes, this test may have failed due to the
associated slips. If such errors exist, first resolve them, and then repeat
this test.
5. Execute the test board PCSS long command on both Expansion
Interface circuit packs and follow procedures for Test #242 to determine
if the problem lies with one of the Expansion Interface circuit packs, the
lightwave transceivers, or the fiber itself.
PASS The tone was successfully transmitted in both directions. Both Expansion
Interface circuit packs and their lightwave transceivers are functioning
properly.
Table 10-212. TEST #241 Expansion Interface 2-Way Transmission Test
— Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page