Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1041PR-MAINT (Maintenance Processor [TN790 RISC Systems])
10
MTP Analog Loop Around Test (#103)
This test is a nondestructive test. The test does a loop around by using the MTP
INADS channel. Test data is sent through the modem out toward the INADS
trunk. The data is looped around before the actual trunk, and it comes back into
the on-board modem. The data is then verified for integrity. The internal modem
is tested when the internal modem is selected. The external modem is tested
when the external modem is selected.
When an external modem is administered in place of the internal modem, the test
loops data in the MTP DUART ahead of the connection to the external modem.
This test also causes the MTP DUART to verify that Clear-To-Send (CTS) is
being supplied by the modem.
NOTE:
The test does not send any data onto the INADS trunk. However, to pass,
the test does require the trunk to be present
PASS MTP detected a loop current on the remote access port.
1. If the system cannot call INADS, or INADS cannot contact the system,
check with the local Central Office for problems with the INADS trunk,
and verify that the INADS number is correct. Approved external
modems with factory default settings are expected to work if
administered correctly using the change system-parameters
command.
Table 10-356. TEST #103 MTP Analog Loop Around Test
Error
Code
Test
Result Description/ Recommendation
100 ABORT The test did not complete within the allowable time period.
1. Retry the command.
1000 ABORT System software resources required for this test are not available.
1. Retry at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 10-355. TEST #102 MTP Outpulse Relay Test Continued
Error
Code Test Result Description/ Recommendation
Continued on next page