DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-677HYB-LINE (Hybrid Line)
10
a. Indicates a defective data link. An off-board problem was detected by
port circuit. Verify that the Hybrid set is connected and that the EPF test
passes. If data transmission problems are experienced, check for
defective wiring or a defective voice terminal, or move terminal closer to
the switch (in terms of feet of wire from the jack to the switch). If the
problem still exists, replace the circuit pack. Once the problem has been
resolved, the alarm is retired after a predetermined period of time.
b. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors
(if any).
c. This error type is logged when the port in question is busied out by
maintenance personnel. Make sure port is released from busyout via the
release port PCSSpp command.
d. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
e. This indicates that the EPF has been turned off due to an overcurrent
condition at the voice terminal. Check for defective wiring or a damaged
jack, and make sure the voice terminal is a Hybrid set. Once the problem
has been resolved, the alarm is retired after a predetermined period of
time.
f. This indicates that the voice terminal has probably been disconnected or
that there is a problem in the wiring to the terminal. Make sure that the
voice terminal is connected or check for defective wiring to the voice
terminal.
g. Note that Error Types 769 and 1281 by themselves create Warning alarms
only, but if both are present, a Minor alarm is logged.
h. This indicates that there is something wrong with the data link to the voice
terminal. An in-line maintenance error has generated an off-board
warning. Ignore it if there are no complaints. Otherwise, make sure the
voice terminal is connected, check for defective wiring, check for a
defective voice terminal, and move voice terminal closer to the switch (in
terms of feet of wire from the jack to the switch). If the problem still exists,
replace the circuit pack.
i. This indicates that the station went off-hook while in the disconnect state.
Use the status station command to determine the state of the station. The
off-hook should have moved the station to in-service. No system
technician action is necessary.
j. This is the code that is generated when the link between the circuit pack
and the voice terminal is successfully reset. No system technician action
is necessary.