DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-825MET-LINE (MET Line)
10
Table 10-277. TEST #62 MET Line Ringer Update Test
Error
Code
Test
Result Description/ Recommendation
3 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this
port. If this error type is present, then release the port via the
release station <extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at one-minute intervals a maximum of five
times.
4. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port
may be busy with a valid call. Use the display port PCSSpp command
to determine the station extension, attendant number, or trunk
group/member number of the port. Use the status station, status
attendant, or status trunk command to determine the service state of
the port. If the service state indicates that the port is in use, then the
port is unavailable for certain tests. (Refer to the "Status Commands"
section in Chapter 8, ‘‘
Maintenance Commands and Trouble-Clearing
Aids’’ for a full description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in use (off-hook) if
the handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
PASS Hybrid Station Ringer Update passed.
1. If complaints still exist, investigate using other circuit pack tests,
and by examining the terminal, wiring, and connections.
Continued on next page