Maintenance Object Repair Procedures
Page 10-1357TIE-DS1 (DS1 Tie Trunk)
10
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some of the tone
detectors may be out of service. Issue the list measurements
tone-receiver command to display basic information about the system’s
tone receivers.
1. Look for TTR-LEV errors in the error log. If present, refer to the
TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the error log. If present, refer to the
TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1 minute intervals for a
maximum of 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a user for a valid call. Use the display port
UUCSSpp command to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1 minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1018 ABORT Test disabled via administration. This only applies to analog stations.
1. To enable test, set the Test field on the station administration screen
for the particular analog station being tested to "y." Use the change
station <extension> command.
1020 ABORT The test did not run due to a previously existing error on the specific port or
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or circuit
pack, and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1 minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-472. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page