Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1380TIE-TRK (Tie Trunk)
10
Table 10-478. TEST #36 Audit Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1006 ABORT (TN439 and TN497 circuit packs only.) The port is in the out-of-service
state. The test cannot be run.
1. Retry the command once the port is in service.
2100 ABORT Could not allocate the necessary system resources to run the test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, escalate the problem.
FAIL Internal System Error.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS This test passed. Translation information was successfully updated on the
circuit pack.
1. If signaling troubles are reported, verify translation information for this
port.
(Non-TN439 and non-TN497 circuit packs only.) If the trunk is busied out,
the test does not run, but it does return PASS.
To verify that the trunk is in-service:
1. Enter status trunk command to verify that the trunk is in-service.
If the trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release trunk command to put trunk back into in-service.
3. Retry the test command.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Continued on next page