DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-833MODEM-PT (Modem Pool Port)
10
Hardware Error Log Entries and Test to Clear
Values
Note:
a. This error type indicates that the circuit pack has been removed or has
been insane for more than 21 minutes. To clear the error, reinsert or
replace the circuit pack.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Modem Pool Conference Test,
for example, you may also clear errors generated
from other tests in the testing sequence. The tests in this section do not apply to
Combined Modem Pool conversion resources. The standard Digital Line and/or
Analog Line port tests are run on the ports associated with the Combined Modem
Pool. The test descriptions for those maintenance objects (MOs) should be
consulted when repairing Combined Modem Pool arrangements.
For example, you may also clear errors generated from other tests in the testing
sequence. The tests in this section do not apply to Combined Modem Pool
conversion resources. The standard Digital Line and/or Analog Line port tests
are run on the ports associated with the Combined Modem Pool. The test
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Modem Pool Port Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
18 0 busyout PCSS WARNING OFF release port PCSSpp
130 (a) None WARNING ON test port PCSSpp sh
257 Conversion
Resource Loop Test
(#98)
MINOR ON test port PCSSpp sh r 3
513 Modem Conference
Test(#97)
MINOR ON test port PCSSpp l r 3
769 Modem NPE
Crosstalk Test (#96)
MINOR ON test port PCSSpp l r 3