DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-338test duplication-interface
8
Output
The following example shows the output for the test ds1-loop 1c07 command,
and assumes that the board in cabinet 1, carrier c, slot 7 is a TN767E DS1 board.
The responses display on a test-by-test basis with one line of data for each test
result.
Field descriptions
test duplication-interface
This command performs hardware diagnostic tests on the indicated duplication
interface circuit pack, under the control of the active SPE that tests the
SHDW-CIR, SPE-SELECT, and DUPINT maintenance objects.
SHDW-CIR is associated with that portion of the duplication interface
circuit pack that handles memory shadowing from the active to the
standby SPE
SPE-SELECT is associated with the SPE Select switch located on the front
of the circuit pack
Port Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object
Alt. Name The alternate means of identifying the maintenance object.
Test No The test being executed
Result Test result: Pass, Abort, Fail, No Board, Disabled, or Extra Bd
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test ds1-loop 01C07 ds1/csu-loopback-tests
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C07 DS1-BD 1209 PASS
01C07 DS1-BD 1210 PASS
01C07 DS1-BD 1211 PASS
Command Successfully Completed