DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-42disable administered-connection
8
Feature Interactions
■ The form display for the list configuration software-vintage command
has been modified to allow INADS to determine the hardware
configuration, software vintage, and patch identifier.
■ Because patches are applied on restarts before the system is in normal
operation, no interaction with routine periodic or scheduled maintenance
exists.
■ The flash checksum test acts as a backup check to ensure entire field
update files are applied correctly. When the flash Checksum Test fails, a
MAJOR on-board alarm is raised on the processor/memory circuit pack.
Maintenance runs a data consistency test on a daily basis to check that
copies of translations, announcements, and software files are consistent
across both processors in a High or Critical Reliability System. If the test
detects a difference, a minor, off-board alarm is generated.
■ When checking software, the test compares the memory resident software
version and the patch identifier. It also searches for the presence of field
update files. If found, it compares the old and new patch identifiers to
ensure that the same patch file id is loaded on each processor. If the
software or update files are inconsistent, the list configuration software
command displays the patch file status.
disable administered-connection
This command stops both scheduled and periodic testing and stops processing
of in-line errors for all or selected administered connections.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
copy
update-file
override
Copies update files from active
SPEs to standby SPEs, regardless
of the dates.
Examples:
copy update-file
copy update-file override
init
inads
none see below.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
disable
administered-
connection
ac
number
all
Number of the administered
connection
Selects all administered connections
Examples:
disable administered-connection all
disable administered-connection 1
disable administered-connection 128
init
inads
craft
cust
rcust
mis
none none