DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-921PDMODULE, TDMODULE (Data Module)
10
■ EPF inquiry — The status of the EPF is sent uplink. EPF is not used for data
modules.
■ ID Request — A request is made to the data module for its status. The
data module sends its configuration information and health information
back. This information is checked and a pass/fail result is provided.
■ Ringer Update — This updates the data module’s ringer state according
to processor records.
■ Translation Update — This is a message normally used with digital
stations to refresh the default value that causes the station to send
touch-tones only in the primary information channel. This test is not used
with data modules.
Table 10-309. TEST #17 Data Module Audits Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT Switchhook audit timed out.
1. Verify the data module is connected to the PBX and repeat the test.
2. If the test aborts, replace the data module and repeat the test.
3. If the test continues to abort, replace the circuit pack and repeat the test.
4. If the test continues to abort, escalate the problem.
2 ABORT ID request fails, health bit is defective, or no response from on-board
microprocessor.
1. Verify that the correct data module type (PDM versus TDM) is
administered.
2. If the test aborts, replace the data module and repeat the test.
3. If the test aborts, replace the circuit pack and repeat the test.
4. If the test continues to abort, escalate the problem.
3 ABORT No response from EPF audit.
4 ABORT Internal System Error.
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at one-minute intervals a maximum of five times.
3. If the test continues to abort, escalate the problem.
Continued on next page