DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-883M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
1003 ABORT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of tone detectors present, or some
tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to
TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to
TONE-PT Maintenance documentation.
3. If neither condition exists, retry the command at one-minute
intervals a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid ISDN-PRI Test Call. Use the list
isdn-testcall command to determine which call is using the port (from
the M/T Port column). Either wait for the test call to complete (as
indicated in the Start Time and Duration fields of the above display), or
abort the test call with the clear isdn-testcall tg/mem command, where
tg/mem is determined from the B-channel field of the above display.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
2100 ABORT System resources required to run this test are not available.
1. Retry the test at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-297. TEST #13 Digital Port Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page