Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-557DUPINT (Duplication Interface Circuit Pack)
10
c. An Aux value of blank or 65317 is valid. The 65317 aux value means the
Duplication Interface circuit pack reported the trouble, while the blank
means the software detected the trouble.
d. This could be caused by mismatched numbers of Processor Interface
(TN765) or Packet Control (TN778) circuit packs in the two SPEs or by a
defective Duplication Interface (TN772) Circuit Pack. If the Duplication
Interface Circuit Pack is defective and becomes part of the Standby SPE,
then memory shadowing does not work. Follow the procedures given for
the FAIL case of Common Shadow Circuit M-Bus Time-Out Query Test
(#285) in the SHDW-CIR section.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below. By
clearing error codes associated with the
Duplication Interface Circuit Pack Status
Query Test,
for example, you may also clear errors generated from other tests in
the testing sequence.
For example, you may also clear errors generated from other tests in the testing
sequence.
Aux
Data Description
1 or
3
Duplication Interface circuit pack A lost handshaking with Duplication
Interface circuit pack B.
2 MTP lost handshaking with the Duplication Interface circuit pack.
221 Duplication Interface circuit pack reported the trouble.
65315
or
65503
Duplication Interface circuit pack A lost contact with Duplication
Interface circuit pack B.
Blank,
65313,
or
65501
If reported against Duplication Interface circuit pack A, Duplication
Interface circuit pack A lost handshaking with Maintenance/Tape
Processor A.
If reported against Duplication Interface circuit pack B, Duplication
Interface circuit pack A lost handshaking with Maintenance/Tape
Processor B.