Page A-111test card-mem
A
If all of the available maintenance resources are currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
test card-mem
Help Messages
If the system technician presses HELP after entering "test card-mem", the following
message is displayed for a simplex switch configuration:
Enter [’long’ or ’short’], [’repeat’ (1-100)
or ’clear’], [’schedule’]
For a duplex switch configuration, the following message will be displayed:
Enter [cabinet(1)];carrier(A-B), [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the SPE is not active, the following message will be displayed:
Command must be executed from active SPE
If the carrier entered is invalid, the following message will be displayed:
"entered value" is an invalid identifier;
press RETURN to execute modified command
If the NETCON board is not TN777B, the following message is displayed:
Must install TN777B circuit pack
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If the standby is entering maintenance mode when this command is executed, then the
following message is displayed:
Cannot interrupt Standby SPE while entering
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the following
message is displayed:
Standby SPE memory not refreshed;
use the "refresh spe-standby" command.