DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-399test trunk
8
Field descriptions
test trunk
This command performs hardware diagnostic tests on an entire trunk group or an
individual trunk group member, depending on the options entered.
Port The port address: cabinet-carrier-slot-circuit
Maintenance
Name
Maintenance object name: TONE-BD, TONE-PT, and TDM-CLK.
Alt. Name Not applicable.
Test No Test being executed
Result Test result: PASS, ABORT, FAIL, NO BOARD, DISABLED, EXTRA
BD.
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test tone-clock 1a
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A TONE-BD 46 PASS
01A TONE-BD 52 PASS
01A TONE-PT 40 PASS
01A TONE-PT 41 PASS
01A TDM-CLK 148 PASS
01A TDM-CLK 149 PASS
01A TDM-CLK 150 PASS
01A TDM-CLK 151 PASS
01A TDM-CLK 574 PASS
Command Successfully Completed