Maintenance Object Repair Procedures
Page 10-1330TDM-BUS (TDM Bus)
10
TDM Bus Clock Parameter Update Test (#151)
This action updates the Tone-Clock internal circuit pack parameters. Tone-Clock
circuit pack:
Disable in-line duplication status messages.
Disable in-line subrate frame maintenance messages (TN768, TN780
only).
Set the PPM threshold at 60 PPM for TN768 and TN780. Set the PPM
threshold at 85 PPM for TN2182.
Enable PPM threshold switching
Set the number of slips to trigger
loss of signal
- currently 30 per 5
millisecond period
Enable the on-board synchronization switching algorithm (see above)
Enable holdover operation (TN2182 only).
This is not a test and will always pass without identifying or reporting any
Tone-Clock circuit pack errors.
PASS The Tone-Clock circuit pack does not detect timing any PPM errors. This
indicates that the external synchronization timing source is valid or that the
system synchronization reference is a Tone-Clock circuit pack. The status
synchronization command should be used to verify that the desired
synchronization reference is providing timing for the system.
Table 10-461. TEST #151 TDM Bus Clock Parameter Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The Tone-Clock circuit pack parameters have been successfully updated.
Continued on next page
Table 10-460. TEST #150 TDM Bus Clock PPM Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page