DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1437UDS1-BD (UDS1 Interface Circuit Pack)
10
Figure 10-96. TN464C/D DS1 Option Jumpers
The option switch located on the component side of the TN464E/F circuit pack
must be set correctly. Figure 10-97
shows how to configure the circuit pack for
24-channel or 32-channel DS1. The channel selection must match the
parameters administered on the corresponding DS1 Circuit Pack Form. (US
applications use 24 Channels.)
Insert the jumpers into the blocks
so as to join the center row of
pins and the row designating the
desired options.
120 OHM
32 CHNL
24 CHNL
75 OHM