DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-479DS1-BD (DS1 Interface Circuit Pack)
10
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the
circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been missing
for 15 minutes. Warning alarms are also raised against any ports administered on the circuit pack.
1324 Any Loss of Signal Alarm Inquiry
Test (#138)
WARNING OFF test board PCSS
1538 (q) Any MINOR ON
1793 Any Blue Alarm Inquiry Test
(#139)
MAJ/MIN/
WRN **
OFF test board PCSS
1794 Any Blue Alarm Inquiry Test
(#139)
MAJ/MIN/
WRN **
OFF test board PCSS
1795 Any Blue Alarm Inquiry Test
(#139)
MAJ/MIN/
WRN **
OFF test board PCSS
2049 Any Red Alarm Inquiry Test
(#140)
MIN/WRN
3
OFF test board PCSS
2305 Any Yellow Alarm Inquiry Test
(#141)
MINOR OFF test board PCSS
2306 Any Yellow Alarm Inquiry Test
(#141)
MINOR OFF test board PCSS
2561 Any Major Alarm Inquiry Test
(#142)
MIN/WRN
3
OFF test board PCSS
2817 Minor Alarm Inquiry Test
(#143)
MIN/WRN
3
OFF test board PCSS
3073 to
3160 (r)
Any Slip Alarm Inquiry Test
(#144)
MIN/WRN
3
OFF test board PCSS r 6
3329 to
3345 (s)
Any Misframe Alarm Inquiry Test
(#145)
MIN/WRN
3
OFF test board PCSS r 6
3840(t) Any None
3900(u) Any CPE Loopback Jack Test
(#1212)
3901(v) Any Far CSU Loopback Test
(#1213)
3902(w) Any One-Way Span Test (#1214)
3999 (x) Any None
Table 10-159. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page