Maintenance Object Repair Procedures
Page 10-916PDMODULE, TDMODULE (Data Module)
10
1020 ABORT Test disabled via background testing. Use status data-module
command to determine when the data module is available for
testing.
2000 ABORT Response to the test request was not received within the allowable
time period.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort escalate the problem.
2020 ABORT The test did not run due to a previously existing error on the specific
port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the previously existing
error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort escalate the problem.
2500 ABORT Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, escalate the problem.
1,2 FAIL The NPE of the tested port was found to be transmitting in Error Log.
This causes noisy and unreliable connections. Failure Code 1
indicates that the Crosstalk Test failed on the primary channel.
Failure Code 2 indicates that the Crosstalk Test failed on the
secondary channel.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat this test
up to a maximum of 10 times and verify that it continues to pass.
2. If complaints still exist, examine the data module, connections,
and wiring.