Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-741ISDN-SGR (ISDN-PRI Signaling Group)
10
Secondary Signaling Link Hardware Check (#639)
The ISDN-PRI Signaling Group D-Channel port depends on the health of the
DS1/UDS1 Interface circuit pack on which it resides. This test will fail if there are
problems with either the ISDN-PRI Primary D-channel port or the DS1/ UDS1
circuit pack. If there are problems with the ISDN-PRI Secondary Signaling
Channel port (ISDN-LNK or ISDN-PLK), also investigate the DS1/UDS1 circuit
pack.
Figure 10-56. Secondary Signaling Link Hardware Check for PRI over PI
(Test #639)
PASS A message was composed and sent to the Far-end switch. The ISDN PRI
specification allows up to two minutes for a reply.
1. Check the Error Log for ISDN-SGR (ISDN-PRI Signaling Group) for
errors of type 2305 for evidence of a Remote Layer 3 Query failure. If no
new errors were logged since this test was run, then this switch and the
Far-end switch processor can exchange call control messages.
2. If there is still a problem with a particular DS1 ISDN Trunk or PRI
Endpoint Port (B-channel), busyout the trunk or port and run the long
test sequence, paying particular attention to the results of Test #258
(ISDN Test Call).
Table 10-244. TEST #637 Remote Layer 3 Query — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page
PI
TDM
BUS
DS1/UDS1
TO FAR-END
SWITCH HARDWARE
(TN765)
CIRCUIT
PACK CIRCUIT
PACK
INTERFACE