DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-90ANN-BD (Announcement Circuit Pack)
10
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack (in the same
slot as the error indicates) to resolve this error. Or, if the circuit pack is in
the system and the red LED is on, follow the instructions for "Red (alarm)"
in the "Control and Port Circuit Pack Status LEDs" section in Chapter 7,
"LED Interpretation".
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
!
WARNING:
Reseating and/or replacing the circuit pack results in loss of
integrated announcements. See "General Notes" near the beginning
of this Maintenance procedure.
b. Error Type 14 Whenever the Announcement Checksum Test (#209)
fails, this error is logged. The Aux Data indicates the number of the first
defective announcement found. This number corresponds to the
announcement numbers on the announcement form. The extension
relating to the announcement can be determined by the display
announcement command. This error only appears in the Error Log in
conjunction with Error Type 2817. Follow the procedures for Error Type
2817 to troubleshoot Error Type 14.
c. Error Type 23
The circuit pack has been logically administered but not
physically installed. The alarm is cleared when the circuit pack is installed.
d. Error Type 125
A wrong circuit pack is inserted in the slot where this
circuit pack is logically administered. To resolve this problem, either
remove the wrong circuit pack and insert the logically administered circuit
pack OR use the change circuit-pack command to readminister this slot
to match the circuit pack inserted.
e. Error Type 170
Announcement board is not allowed in slot A03 for a
system with Enhanced SCC cabinet. The red led of announcement board
is turned on and the error message "Announcement board is not allowed
in slot A03" is shown on SAT when test/busyout/release board A03
commands are entered. The announcement board must be removed and
inserted into a different slot.
f. Error Type 217 and 267
Indicate that there is more than one TN750
Announcement circuit pack inserted in the system. Remove the alarmed
circuit pack..
g. Error Type 257
This error indicates transient communication problems
with this circuit pack. This error is not service-affecting and no action is
required.