Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1114S-SYN-PT (Speech Synthesis Port)
10
Speech Synthesis SSD Inquiry Test (#167)
This test determines the sanity of the specified port’s Speech Synthesis Device
(SSD). The on-board microprocessor tests the port’s SSD and determines if it is
in a sane (test passes) or insane (test fails) condition. Other ports on the Speech
Synthesis circuit pack continue to function correctly during this type of failure.
Speech Synthesis PSS Handshake Test (#168)
This test verifies control functionality between the on-board microprocessor and
PSS controller. A failure occurs if either of the following events occur:
The on-board microprocessor times out while waiting for the PSS
controller to respond.
An invalid command is received by the on-board microprocessor from the
PSS controller.
Table 10-398. TEST #167 Speech Synthesis SSD Inquiry Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call and therefore unavailable for certain tests. You must wait
until the port is idle (yellow LED if off) before retesting.
1. If the port is idle, retry the command at one-minute intervals a maximum of
five times.
2. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Any FAIL The SSD is insane.
1. Replace the circuit pack.
PASS The SSD is sane. User-reported troubles should be investigated using other
tests and verifying other ports on this circuit pack are working correctly.
Continued on next page