DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-699INADS (INADS Link)
10
INADS (INADS Link)
The INADS Link MO represents the software and communications link required
by the switch to make a call to the Initialization and Administration System
(INADS). The purpose of the INADS Link MO is to check the communications link
between the DEFINITY Generic 1 and INADS and verify that the alarm notification
process works correctly. An INADS technician can test the process remotely to
verify that alarms are reported to INADS, or a system technician may want to test
the connection while on-site at installation time or during subsequent service
calls.
Although the INADS Link MO is never alarmed, the errors are logged. The errors
are only logged as a result of the test inads-link command being issued.
Error Log Entries and Test to Clear Values
The Hardware Error Log entries are described as part of the INADS Link Test
description.
Short and Long Test Sequences
The test inads-link command is different from other test commands. This
command does not have a long or short option, and the test on the INADS Link
does not have an associated test number. When the command is different from
other test commands. This command does not have a long or short option, and
the test on the INADS Link does not have an associated test number. When the
test inads-link command is issued, the user immediately sees either the
"Command successfully completed" or "Command failed" message command is
issued, the user immediately sees either the "Command successfully completed"
or "Command failed" message.
INADS Link Test (no test number)
The INADS Link Test attempts to place a call to INADS (in the background) to
verify the communications link to INADS. When the test inads-link command is
entered, the user immediately sees either "Command successfully completed" or
"Command failed." The "Command failed" message appears when a previously
run command is entered, the user immediately sees either "Command
successfully completed" or "Command failed" The "Command failed" message
appears when a previously run test inads-link command is in progress or the
system has active alarms which must be reported to INADS. The "Command
successfully completed" means the switch will start the attempt to call INADS in
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
INADS none test inads-link INADS Link