Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-304CO-TRK (CO Trunk)
10
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to Table 10-93 for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Aux data 57345 -- Single polarity ringing current
Aux data 57376 -- No loop current on incoming call
Aux data 57408 -- No tip ground detected on outgoing call
Aux data 57424 -- No loop current on outgoing call
Aux data 57484 -- No dial tone on outgoing call
These errors cause the Dial Tone Test (#0) to run and are only considered
a problem if the Dial Tone Test fails (in which case Error Type 1537 also
shows up). In this case, the trunk may be put in "Ready-for-Service" state
(shown as "disconnected" by status command), which allows only
incoming calls. Run the Dial Tone Test (#0) and follow its outlined
procedures.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to warning alarms based on the values used in the set
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
2817 (d) 57484 Dial Tone Test (#0) MAJ/MIN/
WRN
2
OFF test port PCSS l r 1
3073 (d) 57376 None
3329 (d) 57408 None
3329 (d) 57484 Dial Tone Test (#0) MAJ/MIN/
WRN
2
OFF test port PCSS l r 1
3585 (d) 57424 None
3840 (f) 8000 Analog Transmission
(#844-848)
OFF
3841 (f) Analog Transmission
(#844-848)
MINOR OFF test analog testcall UUCSS
pp r 2
Table 10-99. CO Trunk Error Log Entries — Continued
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page