Maintenance Object Repair Procedures
Page 10-111ANN-PT (Announcement Port)
10
Notes:
a. The Announcement circuit pack can exhibit a condition that does not allow
recording.
If the circuit pack gets locked into this state (this is an extremely rare
condition), two of the Announcement Ports on the circuit pack (one of
which is the record port) will be unusable by software. Also, save/restore
announcements will not work since the record port looks busy to the
circuit pack. Note that software does not have any way of knowing this
and attempts to use the ports.
If the circuit pack is locked into this state, the following symptoms are
observed:
FAIL Test failed. Announcements played back on this port
may sound corrupted.
1. Reset the circuit pack via the reset board PCSS
command and then run this test again. If the test
continues to fail, replace the circuit pack (see
Warning).
2. If there are recurring alarms on this port caused by
this test failing, replace the circuit pack even if Step
1 works (see Warning).
!
WARNING:
Replacing the circuit pack results in loss of
integrated announcements. Refer to "General
Notes" near the beginning of this Maintenance
procedure.
PASS This test verifies that the Angel processor can properly
set up this port for playbacks. User-reported troubles on
this circuit pack should be investigated using other port
and circuit pack tests. (Refer to "ANN-BD
(Announcement Circuit Pack)" Maintenance
documentation for a description of the circuit pack
tests.)
Table 10-40. TEST #205 Channel Administration Memory Array (CAMA)
Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page