Page 10-663FL-DATA (Flash Data Consistency)
10
17 FAIL The translations and announcements are different in both SPEs. The
Active SPE has the most current translations and the Standby SPE has
the most current announcements.
18 FAIL The translations and announcements are different in both SPEs. The
standby SPE is the most current.
1. Follow the procedures for Error Code 9.
20 FAIL The load vintages and announcements are different in both SPEs. The
Standby SPE has the most current announcements.
21 FAIL The translations, announcements, and load vintages are different in
both SPEs. The Active SPE has the most current translations and the
Standby SPE has the most current announcements.
22 FAIL The translations, announcements, and load vintages are different in
both SPEs. The Standby SPE has the most current translations and
announcements.
1. Follow the procedures for Error Code 4. Be sure to issue the save
announcements command.
32 FAIL The update files are different in both SPEs. The update file on the
Active SPE is most current.
1. Have INADS issue the copy update-file command. If the update
file copy passes, go to Step 2.
2. Reissue the test card-mem long command to resolve the alarms.
33 FAIL The update files and translations are different in both SPEs. The Active
SPE has the most current update file and translations.
34 FAIL The update files and translations are different in both SPEs. The Active
SPE has the most current update file, and the Standby SPE has the
most current translations.
1. Issue the save translations command to save translations on
both SPEs.
2. Have INADS issue the copy update-file command to copy the
update file from the Active to the Standby SPE.
3. Reissue the test card-mem long command to resolve the alarms.
36 FAIL The update files and load vintages are different in both SPEs. The
Active SPE has the most current update file.
37 FAIL The update files, load vintages, and translations are different in both
SPEs. The Active SPE has the most current update file and
translations.
Table 10-223. TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Test
Result Description/Recommendation
Continued on next page