Maintenance Object Repair Procedures
Page 10-223CAP-MEM (Memory Card Capacity)
10
CAP-MEM (Memory Card Capacity)
Memory Card Capacity tracks the percentage of used translation storage space
on the memory card. Whenever translation space usage on the memory card
reaches 98% of capacity, an alarm is generated. This alarm serves to inform the
user that a larger flash card may be required for the system.
Error Log Entries and Test to Clear Values
Notes:
a. The memory card translation storage space is at least or more than 98%
full.
b. This alarm has been downgraded by the set option command.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table that follows when you
are inspecting errors in the system. By clearing error codes associated with the
"Memory Card Capacity Test," for example, you may also clear errors generated
from other tests in the testing sequence. The "Memory Card Capacity Test" can
be initiated via either the test card-mem long command or after a save
translation command.
1. The WARNING alarm is generated when the alarm is downgraded by using the set option
command.
MO Name (in
Alarm Log) Alarm Level Initial Command to Run Full Name of MO
CAP-MEM MINOR/
WARNING
1
test card-mem long Memory Card Capacity
Table 10-77. Memory Card Capacity Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
1 (a) 112 Memory Card Capacity Test (#1014) MINOR/
WARNING (b)
OFF test card-mem long