Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-291status pri-endpoint
8
Output
The following example shows the output from the status pms-link command.
Field descriptions
status pri-endpoint
This command displays internal software state information for diagnosis and can
help locate facilities with which a PRI endpoint is communicating. Status
information for each of the B-channels making up the PRI endpoint display in
addition to some overall PRI endpoint information.
Physical Link
State
Up, down, or extension not administered; link is considered
administered only if an extension is given in the System Hospitality
form.
Protocol State up, down, or blank if not administered.
Number of
Retries
Number of times the switch has tried to set up the link (only
displayed when the link is down; range 1-999)
Maintenance
Busy
yes or no (technician has or has not busied out the link), blank if
PMS link not administered.
Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status
pri-endpoint
extension
print
PRI endpoint extension to be
displayed (see dial-plan).
Report sent to printer
Examples:
status pri-endpoint 25012
status pri-endpoint 77868
status pri-endpoint 66078 print
init
inads
craft
nms
browse
none none
status pms-link
PMS LINK STATUS
Physical Link State: down
Protocol State: down
Number of Retries: 3
Maintenance Busy? no