Maintenance Object Repair Procedures
Page 10-17ADM-CONN (Administered Connection)
10
Notes:
a. These errors have no specific test associated with them. Refer to Notes b
through p for an explanation and appropriate action.
b. These errors are valid only for administered connection established over
ISDN facilities; only error 127 is valid for administered connection
established over non-ISDN facilities (or between two endpoints on the
same switch).
■ Aux Data 1—Administered connection establishment failed
■ Aux Data 2—Active administered connection failed; attempting
reestablishment via auto restoration
■ Aux Data 3—Auto restoration failed
■ Aux Data 4—Active administered connection failed; attempting
reestablishment via fast retry
■ Aux Data 5—Fast retry failed
c. These errors are typically associated with administrative problems and are
not expected to be of a temporary nature. Therefore, the administered
connection is not retried and the failure is alarmed immediately (the alarm
threshold specified by the customer is ignored).
d. The address of the destination endpoint is: an unassigned number (1);
has an invalid number format (28); or is restricted form terminating calls
("Access Denied") [due to COR (Class of Restriction)]. Verify that the
destination address is correct and that the destination endpoint is
administered. The destination endpoint is not administered on the switch
where this error is logged.
e. A request has been made to use a transit network or common carrier that
cannot be accessed. Check the routing pattern used by this Administered
Connection and verify that the inter-exchange carrier specified is correct.
f. The exact failure cause is unknown or has been mapped to one of these
values. If this is not a temporary condition, try reversing the direction of the
Administered Connection (that is, originate the Administered Connection
from the destination switch). This may yield another failure cause.
111 (a)(b)(c)(q) Any None Any OFF None
127 (a)(b)(c)(g) Any None Any OFF None
Table 10-8. Administered Connection Error Log Entries — Continued
Error Type Aux Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear
Value
Continued on next page